1200 BPS DCM-212 Modem (260-1385A)        Selftest     Faxback Doc. # 7053

ANALOG SELF-TEST MODE

Type "Q", and then type "L" to confirm that the value of the ANALOG LOOP
parameter is now changed to Y. Type "X" to execute the test command. The
modem displays CONNECT, and you are in the selftest mode. Type any
characters on the keyboard. If the DCM 212 is working properly, the
TRANSMIT DATA and RECEIVED DATA indicators blink simultaneously, and the
characters you typed appear on the display. If not, there are problems with
the circuit. Check all cables and connections, and run the test again. To
abort the selftest mode, use the abort character or long space disconnect.